Proven Incineration Solutions Built to Last
Backed by decades of experience, our incinerators are built for reliability, efficiency, and consistent performance.
Built to Last
Durable, long-lasting incineration systems that stand the test of time.
Custom Engineered
Tailored incinerators rugged designed for your specific needs.
Waste Reduction
Effective incineration to reduce waste volume and Costs.
Environmental Safety
Incineration solutions that meet the highest safety and environmental standards.
Our Incinerators
Compact and Rugged Waste Reduction Solutions for Any Industry.

Destructor Junior
1 Re-Adjustable Gas Burner
100,000 BTU Incinomite Burner With Cover
115 Volts
3 Inches of 3,000-Degree Refractory Lining
60-Minute Intermatic Timer
80-100 Lb/Hour Capacity
Charge Door With 2-Inch 3000-Degree Refractory Lining
Only Requires 5’x5’ Space
Secondary chamber available upon request.

Destructor Junior
- 100,000 BTU Incinomite Burner w/Cover
- 115 Volts
- 2 60-Minute Intermatic Timers
- 2 Re-Adjustable Gas Burners
- 3 Inches of 3,000-Degree Refractory Lining
- 80-100 Lb/Hour Capacity
- Charge Door With 2-Inch 3000-Degree Refractory Lining
- Only Requires 5’x5’ Space
- Secondary chamber available upon request.

TC-275 Incinerator
1 Re-Adjustable Gas Burner
115 Volts
2 Inches of Refractory Lining in the Stack
275 Lb Capacity
3 Inches of 3000-Degree Refractory Lining
Counter-Balanced Charge Door With 4″ 3000-Degree Refractory Lining
Only Requires 10’x10′ Space
Thermocouple Installation to Conserve Fuel
Secondary chamber available upon request.

Destructor
- 1 Re-Adjustable Gas Burner
- 1000 Lb Capacity
- 115 Volts
- 2 Inches of Refractory Lining in the Stack
- 5 Inches of 3000-Degree Refractory Lining
- Counter-Balanced Charge Door with 4″ 3000-Degree Refractory Lining
- Only Requires 10’x10′ Space
- Thermocouple Installation to Conserve Fuel
- Secondary chamber available upon request.

HD 500
500 Lb Capacity
115 Volts
2 Inches of Refractory Lining in the Stack
2 Re-Adjustable Gas Burners
3 Inches Walls, 4 Inch Ends of 3000-Degree Refractory Lining
Counter-Balanced Charge Door With 4-Inch 3000-Degree Refractory Lining
Only Requires 10’x10′ Space
Thermocouple Installation to Conserve Fuel
Secondary chamber available upon request.

Accessories
Adjustable lifting arm for safe and efficient charge door operation
Manual winch and cable system for controlled loading and unloading
Spark arrestor with heavy-duty mesh for enhanced fire safety
Counter-balanced lid assist mechanism to reduce operator strain
Removable ash screen and containment components
Heavy-gauge steel construction for outdoor and high-heat environments
Designed to integrate seamlessly with compatible incinerator models
Manuals and Burner Breakdowns

Click to Down
- Midco J83-DS Manual
- Midco J83-DS Replacement Parts
- Wayne Combustion Manual EHA Oil Burner
Ready to Upgrade Your Incinerator? Find Out How We Can Help.
Request at Quote Today
Get personalized incineration solutions taliored to your specifi needs. Contact us today at 205-589-6720.