Proven Incineration Solutions Built to Last

Backed by decades of experience, our incinerators are built for reliability, efficiency, and consistent performance.

Built to Last

Durable, long-lasting incineration systems that stand the test of time.

Custom Engineered

Tailored incinerators rugged designed for your specific needs.

Waste Reduction

Effective incineration to reduce waste volume and Costs.

Environmental Safety

Incineration solutions that meet the highest safety and environmental standards.

Our Incinerators

Compact and Rugged Waste Reduction Solutions for Any Industry.

Destructor Jr.

Destructor Junior

  • 1 Re-Adjustable Gas Burner

  • 100,000 BTU Incinomite Burner With Cover

  • 115 Volts

  • 3 Inches of 3,000-Degree Refractory Lining

  • 60-Minute Intermatic Timer

  • 80-100 Lb/Hour Capacity

  • Charge Door With 2-Inch 3000-Degree Refractory Lining

  • Only Requires 5’x5’ Space

  • Secondary chamber available upon request.

Destructor Junior

  • 100,000 BTU Incinomite Burner w/Cover
  • 115 Volts
  • 2 60-Minute Intermatic Timers
  • 2 Re-Adjustable Gas Burners
  • 3 Inches of 3,000-Degree Refractory Lining
  • 80-100 Lb/Hour Capacity
  • Charge Door With 2-Inch 3000-Degree Refractory Lining
  • Only Requires 5’x5’ Space
  • Secondary chamber available upon request.

TC-275 Incinerator

  • 1 Re-Adjustable Gas Burner

  • 115 Volts

  • 2 Inches of Refractory Lining in the Stack

  • 275 Lb Capacity

  • 3 Inches of 3000-Degree Refractory Lining

  • Counter-Balanced Charge Door With 4″ 3000-Degree Refractory Lining

  • Only Requires 10’x10′ Space

  • Thermocouple Installation to Conserve Fuel

  • Secondary chamber available upon request.

Destructor

  • 1 Re-Adjustable Gas Burner
  • 1000 Lb Capacity
  • 115 Volts
  • 2 Inches of Refractory Lining in the Stack
  • 5 Inches of 3000-Degree Refractory Lining
  • Counter-Balanced Charge Door with 4″ 3000-Degree Refractory Lining
  • Only Requires 10’x10′ Space
  • Thermocouple Installation to Conserve Fuel
  • Secondary chamber available upon request.

HD 500

  • 500 Lb Capacity

  • 115 Volts

  • 2 Inches of Refractory Lining in the Stack

  • 2 Re-Adjustable Gas Burners

  • 3 Inches Walls, 4 Inch Ends of 3000-Degree Refractory Lining

  • Counter-Balanced Charge Door With 4-Inch 3000-Degree Refractory Lining

  • Only Requires 10’x10′ Space

  • Thermocouple Installation to Conserve Fuel

  • Secondary chamber available upon request.

    Accessories

    • Adjustable lifting arm for safe and efficient charge door operation

    • Manual winch and cable system for controlled loading and unloading

    • Spark arrestor with heavy-duty mesh for enhanced fire safety

    • Counter-balanced lid assist mechanism to reduce operator strain

    • Removable ash screen and containment components

    • Heavy-gauge steel construction for outdoor and high-heat environments

    • Designed to integrate seamlessly with compatible incinerator models

    Manuals and Burner Breakdowns

    Click to Down

    • Midco J83-DS Manual
    • Midco J83-DS Replacement Parts
    • Wayne Combustion Manual EHA Oil Burner

    Ready to Upgrade Your Incinerator? Find Out How We Can Help.

    Request at Quote Today

    Get personalized incineration solutions taliored to your specifi needs. Contact us today at 205-589-6720.